SPECIFICATION SHEET • SI METRIC
CAT: ELECTRICAL-ENERGY

Compressed-Air Compressor Power

Estimate compressor input power from free-air delivery, absolute pressure ratio, and compression efficiency.

OPERATING LIMITS — Isothermal reference-power calculation only; verify compressor maps, polytropic efficiency, inlet conditions, aftercooler losses, pressure setpoints, controls, and motor service factor.
INPUT DESIGN PARAMETERS (SI)
m³/min
bar
bar
%
CALCULATED SPECIFICATION OUTPUT
Estimated Compressor Input Power
⚡
96.99 kW
Absolute Pressure Ratio7.91 ratio
Specific Compressor Power4.8496 kW per m³/min

Related planning checklists

This calculator appears in the following engineering planning checklists:

1. Compressed-Air Demand Sizing2. Compressed-Air Compressor Power3. Motor Current Estimation4. Plant Energy Consumption & Cost5. Industrial CO2 Carbon Emissions

Technical Methodology & Engineering Principles

GOVERNING EQUATION
Isothermal reference power = p₁ × Q₁ × ln(p₂/p₁); compressor input power = reference power / efficiency.
Assumptions & Scope

First-pass isothermal reference using free-air delivery at inlet conditions. Final compressor selection must use manufacturer curves, polytropic/adiabatic efficiency, aftercooler pressure drop, ambient conditions, controls, and motor service factor.

Operating Range & Boundary

Use finite, physically meaningful inputs within the stated operating assumptions.