Sieve Analysis & Particle Size (D80/D50)
Interpolate D80, D50, and D20 particle sizes from cumulative passing percentages in sieve analysis.
OPERATING LIMITS — Interpolation is valid only inside bracketing measured points.
INPUT DESIGN PARAMETERS (SI)
µm
%
µm
%
CALCULATED SPECIFICATION OUTPUT
D80 Size (80% Passing)
145.3 µm
| D50 Size (Median) | 120.3 µm |
Related planning checklists
This calculator appears in the following engineering planning checklists:
Laboratory QA/QC Analytical Pipeline
R&D Chemist1. Chemical Titration & Molarity2. Lab-to-Plant Scale-Up Factor3. Sieve Analysis & Particle Size (D80/D50)
Technical Methodology & Engineering Principles
GOVERNING EQUATION
Fit passing percentage linearly against ln(particle size) between two bracketing sieve points, then solve the line for 80% and 50% passing.
Assumptions & Scope
Log-linear interpolation is used only between two valid bracketing points. It is not extrapolated and does not replace a complete particle-size distribution.
Operating Range & Boundary
Larger sieve > smaller sieve > 0 and its passing percentage must be higher; each requested percentile must lie between the two passing values.