SOURCE-LED REFERENCE NOTES

Dissolved Oxygen Dynamics, Raceway Aeration Efficiency & SOTR

Calculating Standard Oxygen Transfer Rate (SOTR), Actual Oxygen Transfer Rate (AOTR), and paddlewheel aerator kW requirements.

SHOWING 55 OF 55 EXHAUSTIVE ARTICLES
ARTICLES (55)
COMMERCIAL AQUACULTURE
1 min reference note

Dissolved Oxygen Dynamics, Raceway Aeration Efficiency & SOTR

Source notes β€” linked publications and standards below; organisations and authors named there do not author or endorse this page.

1. AOTR Aeration Equation

AOTR = SOTR Γ— [ (Ξ² Γ— C* - C) / 9.09 ] Γ— 1.024^(T-20) Γ— Ξ±
PEER-REVIEWED TEXTBOOK & JOURNAL CITATIONS
  • Boyd, C. E. (1998). Water Quality for Pond Aquaculture. Auburn University. [Access Reference]